Requirements For Fireworks And Firecrackers Warehouse

Jun 18, 2020

Leave a message

Regarding the storage of fireworks and firecrackers, relevant regulations and standards have clear requirements.

Warehouse area plan and external space The location of fireworks storage warehouse should meet the needs of the area plan. New construction, reconstruction, and expansion of fireworks and firecracker warehouse construction projects shall be subject to safety condition certification and safety evaluation, and it is necessary for their safety equipment to be planned, constructed, and put into operation together with the main project.

Before the fireworks and firecrackers storage warehouse construction project is completed and put into operation, it is necessary to carry out inspection in accordance with relevant regulations; after passing the inspection, it can be put into operation. The safety distance between the C-class fireworks storage warehouse and the township planning margin with an accounting of 3 tons to 4 tons should not be less than 130 meters; with residential areas, campuses, kindergartens, industrial areas, gas stations, dangerous goods production companies, Rongxing The safety distance between densely populated areas such as resident areas, hospitals, tourist areas, etc. should not be less than 80 meters; the safety distance from national railway lines should not be less than 50 meters, and the safety distance from roads above grade two and high-voltage transmission lines should not be less than 40 meters. . The safety distance between the C-class fireworks storage warehouses and township planning margins with an accounting of 2 tons to 3 tons should not be less than 120 meters; and the residential areas, campuses, kindergartens, industrial areas, gas stations, dangerous goods production companies, Rongxing The safety distance between densely populated areas such as resident areas, hospitals, tourist areas, etc. should not be less than 75 meters; the safety distance from national railway lines should not be less than 50 meters, and the safety distance from roads above grade two and high-voltage transmission lines should not be less than 38 meters. . The safety distance between the C-class fireworks storage warehouse and the township planning boundary with an accounting dose of less than 2 tons should not be less than 110 meters; it should be at least 110 meters away from residential areas, campuses, kindergartens, industrial areas, gas stations, dangerous goods production companies, and Rongxing residence The safe distance between densely populated areas such as hospitals and tourist areas should not be less than 65 meters; the safe distance from national railway lines should not be less than 50 meters, and the safe distance from second-grade roads and high-voltage transmission lines should not be less than 35 meters. The fireworks storage warehouse shall not exceed the limited dose and type of fireworks storage. A symbol of vehicle speed limit should be set in the obvious position in the storage area. It is necessary to set a safety warning symbol on the outside of the warehouse wall and in the obvious position in the storage area.

Safety equipment The warehouse area should be equipped with high-level water tanks, fire-fighting water storage tanks or outdoor fire hydrants according to local fire water supply conditions, or use natural rivers and ponds. The water consumption for firefighting should be no less than 15 liters per second, and the continuous water supply time should be no less than 2 hours. The storage water for fire protection shall have the usual methods of non-passive use and anti-freezing, and shall be replenished in time after use. Fire-fighting equipment and devices shall be managed by designated personnel, and shall be regularly checked, repaired, maintained, replaced and added to ensure their usefulness, and it is strictly forbidden to occupy, bury and use them. There is usually no circuit and lighting equipment in the warehouse. If it is really necessary, the lighting lamp should be sealed and explosion-proof, to prevent the use of other electrical equipment, and it is strictly forbidden to build temporary electrical equipment near the warehouse. The external lines should be laid or laid underground with armored cables. External electrical lines are prevented from passing over the warehouse. The lightning protection method of the warehouse should conform to the provisions of the "Building Lightning Protection Plan Standard". The lightning protection method of the warehouse is based on the level I plan. Small and medium-sized explosive battles and fireworks or fireworks bullets with a single commodity charge of less than 40 grams can be used. According to the level Ⅱ plan, and regularly inspected every year according to relevant regulations It is necessary for the warehouse to set up alarm phones and monitoring equipment, and adopt appropriate anti-theft methods.